Selection
Tables
Maximum
flow capacity for these valves is determined by the internal operator,
spool type and operating pressure. Contact the Dynex sales department
for complete specifications and for a review of any application which
requires operating above the nominal flow or pressure, or higher than
normal operating temperatures.
Model
D03 - N.F.P.A. D03/ISO 03 Pattern
|
Operator
Options
|
Dynex
Series
|
Nominal
Flow
|
Maximum
Flow
|
Maximum
Pressure
|
|
U.S.
gpm
|
L/min
|
U.S.
gpm
|
L/min
|
psi |
bar |
|
|
Manual
Lever
|
6100
|
8
|
30
|
15
|
57
|
5000
|
350
|
|
Solenoid
Direct
|
6500
|
8
|
30
|
15
|
57
|
5000
|
350
|
|
External
Hydraulic Pilot
|
6800
|
8
|
30
|
15
|
57
|
5000
|
350
|
|
External
Air Pilot
|
6900
|
8
|
30
|
15
|
57
|
5000
|
350
|
|
Model HP03 - Special High Pressure Pattern
|
Operator
Options
|
Dynex
Series
|
Nominal
Flow
|
Maximum
Flow
|
Maximum
Pressure
|
|
U.S.
gpm
|
L/min
|
U.S.
gpm
|
L/min
|
psi |
bar |
|
|
Manual
Lever
|
6100
|
5
|
19
|
15
|
57
|
10 000
|
700
|
|
Solenoid
Direct
|
6500
|
5
|
19
|
15
|
57
|
10 000
|
700
|
|
External
Hydraulic Pilot
|
6800
|
5
|
19
|
8
|
30
|
10 000
|
700
|
|
External
Air Pilot
|
6900
|
5
|
19
|
8
|
30
|
10 000
|
700
|
|
Model
D05 - N.F.P.A.
D05/ISO 05 Pattern
|
Operator
Options
|
Dynex
Series
|
Nominal
Flow
|
Maximum
Flow
|
Maximum
Pressure
|
|
U.S.
gpm
|
L/min
|
U.S.
gpm
|
L/min
|
psi |
bar |
|
|
Manual
Lever
|
6100
|
20
|
76
|
20
|
76
|
5000
|
350
|
|
Solenoid
Direct
|
6500
|
20
|
76
|
40
|
151
|
5000
|
350
|
|
External
Hydraulic Pilot
|
6800
|
20
|
76
|
20
|
76
|
5000
|
350
|
|
External
Air Pilot
|
6900
|
20
|
76
|
20
|
76
|
5000
|
350
|
|
Model
HP05 - Special High Pressure Pattern
|
Operator
Options
|
Dynex
Series
|
Nominal
Flow
|
Maximum
Flow
|
Maximum
Pressure
|
|
U.S.
gpm
|
L/min
|
U.S.
gpm
|
L/min
|
psi |
bar |
|
|
Solenoid
Direct
|
6500
|
5
|
19
|
25
|
95
|
8000
|
560
|
|
External
Hydraulic Pilot
|
6800
|
5
|
19
|
10
|
38
|
8000
|
560
|
|
External
Air Pilot
|
6900
|
5
|
19
|
10
|
38
|
8000
|
560
|
|
Model
D05H - N.F.P.A.
D05/ISO 05 Pattern
(With
"X"
and "Y" ports for external pilot and drain)
|
Operator
Options
|
Dynex
Series
|
Nominal
Flow
|
Maximum
Flow
|
Maximum
Pressure
|
|
U.S.
gpm
|
L/min
|
U.S.
gpm
|
L/min
|
psi |
bar |
|
|
Solenoid
Pilot
|
6600
|
30
|
114
|
40
|
151
|
5000
|
350
|
|
External
Hydraulic Pilot
|
6800
|
30
|
114
|
40
|
151
|
5000
|
350
|
|
External
Air Pilot
|
6900
|
30
|
114
|
40
|
151
|
5000
|
350
|
|
Model
D08 - N.F.P.A.
D08/ISO 08 Pattern
|
Operator
Options
|
Dynex
Series
|
Nominal
Flow
|
Maximum
Flow
|
Maximum
Pressure
|
|
U.S.
gpm
|
L/min
|
U.S.
gpm
|
L/min
|
psi |
bar |
|
|
Mechanical
Lever
|
6100
|
40
|
151
|
90
|
341
|
5000
|
350
|
|
Solenoid
Pilot
|
6600
|
40
|
151
|
90
|
341
|
5000
|
350
|
|
External
Hydraulic Pilot
|
6800
|
40
|
151
|
90
|
341
|
5000
|
350
|
|
External
Air Pilot
|
6900
|
40
|
151
|
90
|
341
|
5000
|
350
|
|
Model
D08H - N.F.P.A.
D08/ISO 08 Pattern
|
Operator
Options
|
Dynex
Series
|
Nominal
Flow
|
Maximum
Flow
|
Maximum
Pressure
|
|
U.S.
gpm
|
L/min
|
U.S.
gpm
|
L/min
|
psi |
bar |
|
|
Solenoid
Pilot
|
6600
|
80
|
303
|
165
|
625
|
5000
|
350
|
|
External
Hydraulic Pilot
|
6800
|
80
|
303
|
165
|
625
|
5000
|
350
|
|
External
Air Pilot
|
6900
|
80
|
303
|
165
|
625
|
5000
|
350
|
|
VST
Seated Valves - Special HP03 Pattern
|
Operator
Options
|
Dynex
Series
|
Nominal
Flow
|
Maximum
Flow
|
Maximum
Pressure
|
|
U.S.
gpm
|
L/min
|
U.S.
gpm
|
L/min
|
psi |
bar |
|
|
Vent
Function
|
VSTV
|
1
|
3,8
|
2
|
7,6
|
15 000
|
1040
|
|
Two
Position, Two-Way
|
VST22
|
5
|
19
|
10
|
38
|
10 000
|
700
|
|
Two
Position, Three-Way
|
VST23
|
5
|
19
|
10
|
38
|
10 000
|
700
|
|
|
Dynex/Rivett
Inc.
Pewaukee,
WI USA
Ashland, MA USA
Eaton Socon, Cambs. UK
|
|
|
 |
|
Home
| Site Map | Product
Index
| Power Units
| Find
a Distributor | Company
Profile | Contact Dynex | Literature
Copyright
© 2003 -