DETAILED INFORMATION:

Fixed Displacement Selection Tables

Variable Delivery Selection Tables

Split-Flow® Multiple Outlet Pumps

Checkball Pump Service Instructions
(pdf format)

Don't have Acrobat Reader? 

Get Acrobat Reader

 

 


Selection Tables - Split-Flow® Pumps

  • The tables below list Isolator Valve Models and Split-Flow-Cover Models.
  • Output flow is based on typical performance at rated pressure. Refer to full-flow pump specifications.
  • For complete pump model numbers or model codes, dimensions, port information and a review of your application, contact the Dynex sales department.

Isolator Valve Models
The table lists pump series available with isolator valves. One or more pistons can be isolated from the main pump outlet. Note that high pressure pumps are limited to a maximum pressure of 6000 psi (420 bar) when using isolator valves. PF2006 and PF2008 pumps are special mounting models.

Pump
Series
Number
of
Pistons
Output Flow Per Piston
(at 1800 rpm)
Isolator Valve
Model
Number
Port Size
U.S. gpm
L/min

PF2006
6
0.67
2,54
VC2006-1872
1/8 Inch N.P.T.
PF2008
6
0.97
3,67
VC2008-1256
1/4 Inch N.P.T.

PF4011
10
0.75
2,84
VC4015-1845
No. 4 SAE
PF4015
10
1.05
3,97
VC4015-1845
No. 4 SAE
PF4021
10
1.50
5,68
VC6046-1844
No. 4 SAE

PF4018
10
1.21
4,58
VC6046-1755
No. 6 SAE
PF4026
10
1.75
6,62
VC6046-1755
No. 6 SAE
PF4033
10
2.24
8,48
VC6046-1755
No. 6 SAE

PV4018
10
1.21
4,58
VC6046-1755
No. 6 SAE
PV4026
10
1.75
6,62
VC6046-1755
No. 6 SAE
PV4033
10
2.24
8,48
VC6046-1755
No. 6 SAE

PF6033
10
2.42
9,16
VC6033-1756
No. 6 SAE
PF6046
10
3.20
12,11
VC6046-3205
No. 8 SAE

Split-Flow-Cover Models
In split-flow-cover models, the individual piston outputs are grouped together in the pump cover or barrel. The table lists the most common pumps. PF500, PF1000, PF2000 and PF3000 Series pumps are also available with all pistons isolated, providing separate outputs from each piston. A four-way split (4x) PF500 Series pump, for example, has four outlets each supplied by one piston.

For high pressure PF500 pumps, models are available with Coned & Threaded (Autoclave, Butech M/P or equivalent) or BSP (British Standard Pipe) ports. For complete port information and pump model numbers or model codes, contact the Dynex sales department.

Pump
Series
Number
of
Pistons
Pistons per Outlet
(Port Size)
Output Flow per Outlet at 1800 rpm
Outlet 1
Outlet 2
Outlet 1
Outlet 2
U.S. gpm
L/min
U.S. gpm
L/min

PF501
4
2 Pistons
(SAE No. 6)
2 Pistons
(SAE No. 6)
0.10
0,38
0.10
0,38
PF504
4
0.17
0,64
0.17
0,64
PF507
4
0.23
0,87
0.23
0,87
PF510
4
0.34
1,29
0.34
1,29

PF501
4
3 Pistons
(SAE No. 6)
1 Piston
(SAE No. 6)
0.16
0,61
0.05
0,19
PF504
4
0.26
0,98
0.09
0,34
PF507
4
0.35
1,32
0.12
0,45
PF510
4
0.51
1,93
0.17
0,64

PF1001
4
2 Pistons
(SAE No. 4)
2 Pistons
(SAE No. 4)
0.35
1,32
0.35
1,32
PF1002
4
0.70
2,65
0.70
2,65
PF1003
4
1.05
3,97
1.05
3,97
PF1004
4
1.28
4,84
1.28
4,84
PF1006
4
1.80
6,81
1.80
6,81

PF1001
4
3 Pistons
(SAE No. 8)
1 Piston
(SAE No. 4)
0.53
1,99
0.18
0,66
PF1002
4
1.05
3,97
0.35
1,32
PF1003
4
1.58
5,98
0.52
1,97
PF1004
4
1.92
7,27
0.64
2,42
PF1006
4
2.70
10,22
0.90
3,41

PF2007
6
3 Pistons
(SAE No. 8)
3 Pistons
(SAE No. 8)
2.05
7,76
2.05
7,76
PF2008
6
2.90
10,98
2.90
10,98
PF2009
6
3.05
11,55
3.05
11,55
PF2012
6
4.25
16,09
4.25
16,09

PF2007
6
4 Pistons
(SAE No. 6)
2 Pistons
(SAE No. 6)
2.73
10,33
1.37
5,19
PF2008
6
3.87
14,65
1.93
7,31
PF2009
6
4.07
15,39
2.03
7,70
PF2012
6
5.67
21,46
2.83
10,71

PF2007
6
5 Pistons
(SAE No. 8)
1 Piston
(SAE No. 4)
3.42
12,94
0.68
2,57
PF2008
6
4.83
18,28
0.97
3,67
PF2009
6
5.08
19,24
1.02
3,85
PF2012
6
7.08
26,80
1.42
5,37

PF3011
8
4 Pistons
(SAE No. 8)
4 Pistons
(SAE No. 8)
4.15
15,71
4.15
15,71
PF3015
8
4.90
18,55
4.90
18,55
PF3017
8
5.85
22,14
5.85
22,14
PF3021
8
7.35
27,82
7.35
27,82

PF3011
8
5 Pistons
(SAE No. 12)
3 Pistons
(SAE No. 8)
5.19
19,64
3.11
11,77
PF3015
8
6.12
23,16
3.68
13,93
PF3017
8
7.31
27,67
4.39
16,62
PF3021
8
9.19
34,78
5.51
20,86

PF3011
8
6 Pistons
(SAE No. 12)
2 Pistons
(SAE No. 6)
6.22
23,54
2.08
7,87
PF3015
8
7.35
27,82
2.45
9,27
PF3017
8
8.78
33,23
2.92
11,06
PF3021
8
11.02
41,71
3.68
13,93

PF3011
8
7 Pistons
(SAE No. 12)
1 Piston
(SAE No. 6)
7.26
27,48
1.04
3,94
PF3015
8
8.58
32,48
1.22
4,62
PF3017
8
10.24
38,76
1.46
5,53
PF3021
8
12.86
48,68
1.84
6,96

PF4011
10
5 Pistons
(SAE No. 8)
5 Pistons
(SAE No. 8)
3.60
13,63
3.60
13,63
PF4015
10
5.10
19,31
5.10
19,31
PF4021
10
7.50
28,39
7.50
28,39

PF4011
10
7 Pistons
(SAE No. 12)
3 Pistons
(SAE No. 8)
5.04
19,08
2.16
8,18
PF4015
10
7.14
27,03
3.06
11,58

PF4018
10
5 Pistons
(SAE No. 12)
5 Pistons
(SAE No. 12)
6.05
22,90
6.05
22,90
PF4026
10
8.75
33,12
8.75
33,12
PF4033
10
11.20
42,40
11.20
42,40

PV4018
10
5 Pistons
(SAE No. 12)
5 Pistons
(SAE No. 12)
6.05
22,90
6.05
22,90
PV4026
10
8.75
33,12
8.75
33,12
PV4033
10
11.20
42,40
11.20
42,40

PF6033
10
5 Pistons
(1 Inch Flange)
5 Pistons
(1 Inch Flange)
10.85
41,07
10.85
41,07
PF6046
10
15.90
60,19
15.90
60,19

PF6054
10
5 Pistons
(1 Inch Flange)
5 Pistons
(1 Inch Flange)
17.20
65,11
17.20
65,11
PF6070
10
24.15
91,42
24.15
91,42

PV6054
10
5 Pistons
(1 Inch Flange)
5 Pistons
(1 Inch Flange)
17.20
65,11
17.20
65,11
PV6070
10
24.15
91,42
24.15
91,42
PV6080
10
26.25
99,70
26.25
99,70

Fixed Displacement Selection Tables

Variable Delivery Selection Tables

Split-Flow® Multiple Outlet Pumps


Dynex/Rivett Inc.
Pewaukee, WI  USA
Ashland, MA USA
Eaton Socon, Cambs. UK

   
Home | Site Map | Product Index | Power Units | Find a Distributor | About Dynex | Contact Dynex | Literature | Careers

Copyright © 2011 - DYNEX/RIVETT INC.