| Hydraulic
Pumps for Water-Based Fluids |
| Dynex
fixed displacement hydraulic pumps
are compatible with a variety of water-based fluids including
water glycol.
PF1300
Series:
0.31 to 1.42 gpm at pressures to 10 000 psi (1,18
to 5,37 L/min at pressures to 700 bar) at 1800 rpm.
PF4300
Series:
2.2 to 8.2 gpm at pressures to 15 000 psi (8,3 to
31,0 L/min at pressures to 1040 bar) at 1800 rpm.
Refer to
the Selection Tables below for detailed specifications.
Corrosion
Resistant
These
pumps are assembled with stainless steel and other corrosion
resistant parts. The
housing and barrel assembly are treated to provide extra
protection until the final coating is applied.
Single
Fluid Design
In
this checkball pump design, internal bearing lubrication
is provided by the pumped fluid. This eliminates the potential
for cross-fluid contamination which may occur in other
pump designs requiring a secondary oil for lubrication.
The
single-fluid design eliminates the space, labor and
piping cost of a lubrication circuit. It also eliminates
regular maintenance of the lubricating oil.
Oil
& Gas Applications
High pressure
capability and compatibility with water glycol make these pumps
ideal for wellhead safety controls systems and other offshore
oil & gas applications.
|
|
|
| |
|
|
| |
Water
Glycol Pump Applications
PF1300
and PF4300 Series hydraulic pumps are used where water-based
fluids are required:
Wellhead
Safety Control
Blowout
Preventer (BOP) Systems
Subsea
and Marine
Hydraulic
Test-Stands
Hydroform
Presses
Learn
more about
Why Checkball Design
Pumps
Work Better
when using special fluids.
|
|
|
|
|
Pump
Models
|
Flow
at
1200 rpm |
Flow
at
1800 rpm |
Maximum
Pressure |
Rated
Speed
(rpm) |
Maximum
Speed
(rpm) |
|
U.S.
gpm |
L/min |
U.S.
gpm |
L/min |
psi |
bar |
|
| PF1300
Series |
| S.A.E.
Outlet Port: |
|
PF1301-10 |
0.26 |
0,98 |
0.31 |
1,18 |
8000 |
560 |
1800 |
1800 |
|
PF1303-10
|
0.36 |
1,35 |
0.43 |
1,63 |
8000 |
560 |
1800 |
1800 |
|
PF1305-10
|
0.46 |
1,73 |
0.55 |
2,08 |
8000 |
560 |
1800 |
1800 |
|
PF1308-10
|
0.60 |
2,30 |
0.73 |
2,76 |
8000 |
560 |
1800 |
1800 |
|
PF1315-10
|
0.76 |
2,87 |
0.91 |
3,45 |
8000 |
560 |
1800 |
1800 |
|
PF1318-10
|
1.01 |
3,82 |
1.21 |
4,58 |
8000 |
560 |
1800 |
1800 |
|
PF1320-10
|
1.18 |
4,47 |
1.42 |
5,37 |
8000 |
560 |
1800 |
1800 |
|
| Autoclave/Butech
or British Standard Pipe Outlet Port: |
|
PF1301H-10 |
0.25 |
0,95 |
0.30 |
1,14 |
10
000 |
700 |
1800 |
1800 |
|
PF1303H-10
|
0.35 |
1,31 |
0.42 |
1,58 |
10
000 |
700 |
1800 |
1800 |
|
PF1305H-10
|
0.44 |
1,70 |
0.54 |
2,03 |
10
000 |
700 |
1800 |
1800 |
|
PF1308H-10
|
0.60 |
2,26 |
0.72 |
2,76 |
9000 |
630 |
1800 |
1800 |
|
PF1315H-10
|
0.74 |
2,80 |
0.89 |
3,37 |
10
000 |
700 |
1800 |
1800 |
|
PF1318H-10
|
1.00 |
3,78 |
1.20 |
4,54 |
9000 |
630 |
1800 |
1800 |
|
| PF4300
Series |
| S.A.E.
Outlet Port: |
|
PF4303-11 |
1.8 |
6,9 |
2.2 |
8,3 |
8000 |
560 |
1200 |
1800 |
|
PF4304-11
|
2.7 |
10,1 |
3.2 |
12,1 |
8000 |
560 |
1200 |
1800 |
|
PF4305-11
|
3.1 |
11,7 |
3.7 |
14,0 |
8000 |
560 |
1200 |
1800 |
|
PF4306-11
|
3.8 |
14,5 |
4.6 |
17,4 |
8000 |
560 |
1200 |
1800 |
|
PF4308-11
|
4.5 |
17,0 |
5.4 |
20,4 |
8000 |
560 |
1200 |
1800 |
|
PF4309-11
|
5.0 |
18,9 |
6.0 |
22,7 |
8000 |
560 |
1200 |
1800 |
|
PF4310-11
|
5.7 |
21,4 |
6.8 |
25,7 |
8000 |
560 |
1200 |
1800 |
|
PF4312-11
|
6.8 |
25,9 |
8.2 |
31,0 |
8000 |
560 |
1200 |
1800 |
|
| Autoclave/Butech
or British Standard Pipe Outlet Port: |
|
PF4303H-11 |
1.6 |
6,2 |
2.0 |
7,2 |
15
000 |
1040 |
1200 |
1800 |
|
PF4304H-11
|
2.5 |
9,5 |
3.1 |
11,4 |
12
000 |
830 |
1200 |
1800 |
|
PF4305H-11
|
2.9 |
11,0 |
3.6 |
13,3 |
10
000 |
700 |
1200 |
1800 |
|
PF4306H-11
|
3.7 |
13,9 |
4.4 |
16,6 |
10
000 |
700 |
1200 |
1800 |
|
PF4308H-11
|
4.3 |
16,5 |
5.3 |
19,9 |
10
000 |
700 |
1200 |
1800 |
|
PF4309H-11
|
4.8 |
18,2 |
5.9 |
22,3 |
10
000 |
700 |
1200 |
1800 |
|
PF4310H-11
|
5.5 |
21,0 |
6.7 |
25,3 |
10
000 |
700 |
1200 |
1800 |
|
PF4312H-11
|
6.7 |
25,6 |
8.1 |
30,7 |
10
000 |
700 |
1200 |
1800 |
|
Pump
Selection Notes
- Output
flows listed are based on typical performance using 33
SUS (1,9 cSt) water glycol fluid at maximum pressure with
pressurized inlet where required. For PF4300 Series pumps,
consult the Dynex
sales department for a review of applications requiring
operation above the rated speed of 1200 rpm.
- Ordering
these pumps requires a complete model code specifying
shaft, seal and port options.
- Models
with the high pressure "H" option require the
use of outlet port "A" (Autoclave/Butech fitting)
or "B" (British Standard Pipe fitting). Pumps
with ports for standard S.A.E. fittings are not recommended
for operation above 8000 psi (560 bar). Contact the fitting
manufacturer for the pressure rating of the fitting.
|
|
Dynex/Rivett
Inc.
Pewaukee,
WI USA
Ashland, MA USA
Eaton Socon, Cambs. UK
|
|
|
 |
Home
| Site Map | Product
Index
| Power Units
| Find
a Distributor | About Dynex | Contact Dynex | Literature | Careers
Copyright © 2011
- DYNEX/RIVETT INC.
|
|