| Compact,
High-Pressure Piston Pumps |
| PF500
Series fixed displacement pumps operate at pressures to 10 000
psi (700 bar) continuous and 15 000 psi (1040 bar)
maximum intermittent.
Low
Input Power
Input
power requirements, as low as 1 HP at 10 000 psi (0.7 kW
at 700 bar), make these pumps ideal for use in remote locations
with limited power supply.
Flows from
0.22 to 0.70 U.S. gpm (0,83 to 2,65 L/min) at 1800 rpm
are available in four models.
Multiple
Output Pumps
Split-Flow®
models provide multiple outputs for synchronized actuator movement
or multiple function circuits.
These multiple
outlet pumps can efficiently supply flow in a circuit with
changing flow and pressure requirements. This makes them ideal
for Hi-Lo circuits on clamping, pressing and high-pressure tool
applications.
Bi-Directional
Shaft Rotation
With
these fixed displacement pumps the direction of output flow
is constant, regardless of drive shaft rotation. Bi-directional
shaft rotation can be an advantage when using double-ended
electric motors, requiring only one model to be specified.
|
|
|
| |
|
|
| |
Oil
& Gas
Industry Pumps
PF500 Series checkball design pumps,
with individual piston check valves, provide long life
in adverse conditions.
High
pressure capability and low input power requirements make
these pumps ideal for land-based Wellhead
Safety Panel Systems. They especially provide an advantage
on solar or wind-powered systems in remote oil field locations
where power supply is limited.
The
pumps can also be used on portable power packs for high-pressure
torque wrenches and other service tools.
|
|
|
|
|
PF500
Series Selection Table
|
Pump
Models
|
Flow
at
1500 rpm |
Flow
at
1800 rpm |
Rated
Pressure |
Maximum
Pressure |
Rated
Speed
(rpm) |
Maxi-mum
Speed
(rpm) |
|
U.S.
gpm |
L/min |
U.S.
gpm |
L/min |
psi |
bar |
psi |
bar |
|
| S.AE.
Outlet Port: |
|
PF501-11
|
0.17
|
0,66
|
0.21
|
0,79
|
8000
|
560
|
8000
|
560
|
1800
|
3600
|
|
PF504-11
|
0.28
|
1,06
|
0.34
|
1,28
|
8000
|
560
|
8000
|
560
|
1800
|
3600
|
|
PF507-11
|
0.38
|
1,45
|
0.46
|
1,76
|
8000
|
560
|
8000
|
560
|
1800
|
3600
|
|
PF510-11
|
0.57
|
2,16
|
0.69
|
2,59
|
8000
|
560
|
8000
|
560
|
1800
|
3600
|
|
| Autoclave/Butech
or British Standard Pipe Outlet Port: |
|
PF501H-11
|
0.17
|
0,64
|
0.20
|
0,75
|
10
000
|
700
|
15 000
|
1040
|
1800
|
3600
|
|
PF504H-11
|
0.27
|
1,02
|
0.32
|
1,22
|
10
000
|
700
|
15 000
|
1040
|
1800
|
3600
|
|
PF507H-11
|
0.37
|
1,40
|
0.45
|
1,70
|
10
000
|
700
|
15 000
|
1040
|
1800
|
3600
|
|
PF510H-11
|
0.56
|
2,12
|
0.67
|
2,52
|
10
000
|
700
|
15 000
|
1040
|
1800
|
3600
|
|
|
Pump
Selection Notes
-
Output
flows are based on typical performance using 100 SUS (20 cSt) mineral
oil at rated pressure with pressurized inlet where required. Consult
the Dynex sales department
for minimum inlet pressure and for a review of applications requiring
continuous-duty at rated speeds higher than 1800 rpm or lower than
900 rpm.
-
Ordering
these pumps requires a
complete model code specifying seal and port options.
-
Models
with the high pressure "H" option require the use of outlet
port option "A" (Autoclave/Butech fitting) or "B"
(British Standard Pipe Fitting). Pumps with ports for standard S.A.E.
fittings are not recommended for operation above 8000 psi (560 bar).
Contact the fitting manufacturer for the pressure rating of the
fitting.
|
|