PF2000 Series Pumps

DYNEX PF2000 FIXED DISPLACEMENT CHECKBALL PUMPS

4.1 to 8.5 gpm (15,5 to 32,2 L/min) at 1800 rpm
Rated: 3 000 psi (210 bar), Maximum: 10 000 psi (700 bar)

  • Contamination tolerant, for operation in dirty environments.
  • Bi-directional rotation providing constant flow direction regardless of drive shaft rotation.
  • Shaft Options: Standard keyed, Optional spline.
  • Seal Options: Standard Fluorocarbon, Optional EPR seals for use with some phosphate ester fluids, or Fluorocarbon with high pressure shaft seal.
  • Split-Flow® models can supply independent flows from up to six separate outlets.

Pump ModelsFlow at 1500 rpm
U.S. gpm | L/min
Flow at 1800 rpm
U.S. gpm | L/min
Rated Pressure
psi | bar
Max. Intermittent Pressure
(psi)
Max. Intermittent Pressure
(bar)
Rated Speed
(rpm)
Max. Speed
(rpm)
S.A.E. Outlet Port:
PF2007-21903.412,94.115,56000420600042020002800
PF2008-21914.818,35.822,05000350600042020002400
PF2009-21845.119,26.123,13000210400028020002800
PF2012-21857.126,88.532,23000210400028020002400
Autoclave/Butech Outlet Port:
PF2007-29733.412,94.115,5600042010 00070018002800
British Standard Pipe Outlet Port:
PF2007-30553.412,94.115,5600042010 00070018002800
Special Mounting Models, S.A.E. Outlet Port:
PF2006-18083.312,64.015,16000420800056020002400
PF2008-18044.718,05.721,63000210500035020002400
Special Mounting Models, N.P.T.F. Outlet Port:
PF2006-18073.312,64.015,16000420800056020002400
PF2008-18024.718,05.721,63000210500035020002400

Pump Selection Notes

  1. Ordering these pumps requires a complete model code specifying seal and port options.
  2. Output flows listed are based on typical performance using 33 SUS (1,9 cSt) water glycol fluid at maximum pressure with pressurized inlet where required. Consult the Dynex sales department for a review of applications requiring operation below the Minimum speed of 1200 rpm.
  3. Models with the high pressure “H” option require the use of outlet port “A” (Autoclave/Butech fitting) or “B” (British Standard Pipe fitting). Pumps with ports for standard S.A.E. fittings are not recommended for operation above 8000 psi (560 bar). Contact the fitting manufacturer for the pressure rating of the fitting.
 

PF2000 Series – Checkball Piston Pumps – Engineering specifications.

 

Pump Application Guide – An overview of the advantages of checkball pump design in mobile, industrial and marine applications.

 

Checkball Pumps Service, Installation and Operating Instructions.

 

Checkball Pumps (all) – Complete specifications for all models.

Inside Checkball Pump Video Screenshot

Inside the Checkball Hydraulic Pump:
Design and Operating Advantages

An introduction to Dynex checkball hydraulic pumps and their unique design which allows them to operate reliably with a wide range of fluids at high pressures.


Split-Flow Pump Video Screenshot

Split-Flow Hydraulic Pumps for Simplified Circuits

Learn how Dynex hydraulic pumps, with Split-Flow technology, can simplify multiple-function hydraulic systems. With their ability to provide multiple flows from one pump, multiple pumps in a system can be replaced by one Dynex multiple-outlet pump.