Selection Table - Fixed Displacement Pumps
|
Pump
Models
|
Flow
at
1800 rpm |
Rated
Pressure |
Maximum
Intermittent
Pressure |
Rated
Speed
(rpm) |
Maxi-
mum
Speed
(rpm) |
|
U.S.
gpm |
L/min |
psi |
bar |
psi |
bar |
|
| PF500
Series (more information) |
|
S.A.E.
Outlet Port: |
| PF501-11 |
0.21 |
0,79 |
8000 |
560 |
8000 |
560 |
1800 |
3600 |
| PF504-11 |
0.34 |
1,28 |
8000 |
560 |
8000 |
560 |
1800 |
3600 |
| PF507-11 |
0.46 |
1,76 |
8000 |
560 |
8000 |
560 |
1800 |
3600 |
| PF510-11 |
0.69 |
2,59 |
8000 |
560 |
8000 |
560 |
1800 |
3600 |
|
|
Autoclave/Butech or British Standard Pipe
Outlet Port: |
| PF501H-11 |
0.20 |
0,75 |
10 000 |
700 |
15
000 |
1040 |
1800 |
3600 |
| PF504H-11 |
0.32 |
1,22 |
10 000 |
700 |
15
000 |
1040 |
1800 |
3600 |
| PF507H-11 |
0.45 |
1,70 |
10 000 |
700 |
15
000 |
1040 |
1800 |
3600 |
| PF510H-11 |
0.67 |
2,52 |
10 000 |
700 |
15
000 |
1040 |
1800 |
3600 |
|
|
PF1000
Series (more information) |
| S.A.E.
Outlet Port: |
| PF1002-10 |
1.5 |
5,7 |
6000 |
420 |
8000 |
560 |
1800 |
3600 |
| PF1003-10 |
2.1 |
7,9 |
6000 |
420 |
8000 |
560 |
1800 |
3600 |
| PF1004-10 |
2.6 |
9,8 |
6000 |
420 |
8000 |
560 |
1800 |
3600 |
| PF1005-10 |
3.5 |
13,2 |
6000 |
420 |
8000 |
560 |
1800 |
2800 |
| PF1006-10 |
4.1 |
15,5 |
6000 |
420 |
8000 |
560 |
1800 |
2800 |
| PF1007-10 |
5.0 |
18,9 |
4000 |
280 |
6000 |
420 |
1800 |
2800 |
| PF1008-10 |
5.9 |
22,3 |
4000 |
280 |
6000 |
420 |
1800 |
2800 |
|
|
Autoclave/Butech
or British Standard Pipe Outlet Port: |
| PF1002H-10 |
1.5 |
5,7 |
6000 |
420 |
10
000 |
700 |
1800 |
3600 |
| PF1003H-10 |
2.1 |
7,9 |
6000 |
420 |
10
000 |
700 |
1800 |
3600 |
| PF1004H-10 |
2.6 |
9,8 |
6000 |
420 |
10
000 |
700 |
1800 |
3600 |
| PF1005H-10 |
3.5 |
13,2 |
6000 |
420 |
10
000 |
700 |
1800 |
2800 |
| PF1006H-10 |
4.1 |
15,5 |
6000 |
420 |
10
000 |
700 |
1800 |
2800 |
|
|
PF1300
Series Pumps for Water-Based Fluids (more
information) |
|
S.A.E.
Outlet Port: |
| PF1301-10 |
0.31 |
1,18 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF1303-10 |
0.43 |
1,63 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF1305-10 |
0.55 |
2,08 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF1308-10 |
0.73 |
2,76 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF1315-10 |
0.91 |
3,45 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF1318-10 |
1.21 |
4,58 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF1320-10 |
1.42 |
5,37 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
|
|
Autoclave/Butech or British Standard Pipe Outlet Port: |
| PF1301H-10 |
0.30 |
1,14 |
10
000 |
700 |
10 000 |
700 |
1800 |
1800 |
| PF1303H-10 |
0.42 |
1,58 |
10
000 |
700 |
10 000 |
700 |
1800 |
1800 |
| PF1305H-10 |
0.54 |
2,03 |
10
000 |
700 |
10 000 |
700 |
1800 |
1800 |
| PF1308H-10 |
0.72 |
2,73 |
9000 |
630 |
9000 |
630 |
1800 |
1800 |
| PF1315H-10 |
0.89 |
3,73 |
10
000 |
700 |
10 000 |
700 |
1800 |
1800 |
| PF1318H-10 |
1.20 |
4,54 |
9000 |
630 |
9000 |
630 |
1800 |
1800 |
|
| PF2000
Series |
| S.A.E.
Outlet Port: |
| PF2007-2190 |
4.1 |
15,5 |
6000 |
420 |
6000 |
420 |
2000 |
2800 |
| PF2008-2191 |
5.8 |
22,0 |
5000 |
350 |
6000 |
420 |
2000 |
2400 |
| PF2009-2184 |
6.1 |
23,1 |
3000 |
210 |
4000 |
280 |
2000 |
2800 |
| PF2012-2185 |
8.5 |
32,2 |
3000 |
210 |
4000 |
280 |
2000 |
2400 |
|
|
Autoclave/Butech
Outlet Port: |
| PF2007-2973 |
4.1 |
15,5 |
6000 |
420 |
10 000 |
700 |
1800 |
2800 |
|
|
British
Standard Pipe Outlet Port: |
| PF2007-3055 |
4.1 |
15,5 |
6000 |
420 |
10 000 |
700 |
1800 |
2800 |
|
|
Special
Mounting Models: |
| S.A.E.
Outlet Port: |
| PF2006-1808 |
4.0 |
15,1 |
6000 |
420 |
8000 |
560 |
2000 |
2400 |
| PF2008-1804 |
5.7 |
21,6 |
3000 |
210 |
5000 |
350 |
2000 |
2400 |
|
| PF3000
Series (more information) |
| S.A.E.
Outlet Port: |
| PF3011-10 |
8.1 |
30,7 |
6000 |
420 |
8000 |
560 |
1800 |
2800 |
| PF3015-10 |
10.0 |
37,8 |
6000 |
420 |
8000 |
560 |
1800 |
2500 |
| PF3017-10 |
12.0 |
45,4 |
6000 |
420 |
8000 |
560 |
1800 |
2200 |
| PF3021-10 |
14.4 |
54,5 |
4000 |
280 |
6000 |
420 |
1800 |
2500 |
| PF3024-10 |
17.2 |
65,1 |
4000 |
280 |
6000 |
420 |
1800 |
2200 |
|
|
Autoclave/Butech
or British Standard Pipe Outlet Port: |
| PF3011H-10 |
8.1 |
30,7 |
6000 |
420 |
10
000 |
700 |
1800 |
2800 |
| PF3015H-10 |
10.0 |
37,8 |
6000 |
420 |
10
000 |
700 |
1800 |
2500 |
|
| PF4000
Series (more information) |
| S.A.E.
Outlet Port: |
| PF4011-30 |
7.7 |
29,1 |
6000 |
420 |
8000 |
560 |
1800 |
2400 |
| PF4016-30 |
11.1 |
42,0 |
6000 |
420 |
8000 |
560 |
1800 |
2400 |
| PF4018-30 |
12.4 |
46,9 |
6000 |
420 |
8000 |
560 |
1800 |
2400 |
| PF4020-30 |
14.0 |
53,0 |
6000 |
420 |
8000 |
560 |
1800 |
2400 |
|
| Autoclave/Butech
or British Standard PipeOutlet Port: |
| PF4011H-30 |
7.3 |
27,6 |
10 000 |
700 |
10 000 |
700 |
1800 |
2400 |
| PF4016H-30 |
10.5 |
39,7 |
10 000 |
700 |
10 000 |
700 |
1800 |
2400 |
| PF4018H-30 |
12.1 |
45,8 |
8000 |
560 |
10 000 |
700 |
1800 |
2400 |
| PF4020H-30 |
13.7 |
51,9 |
8000 |
560 |
10 000 |
700 |
1800 |
2400 |
|
|
PF4200
Series |
|
S.A.E.
Outlet Port: |
| PF4203-10 |
2.2 |
8,3 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF4205-10 |
3.6 |
13,6 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF4208-10 |
5.2 |
19,7 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF4209-10 |
5.9 |
22,3 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
| PF4210-10 |
6.7 |
25,4 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
|
|
Autoclave/Butech or British Standard Pipe Outlet Port: |
| PF4203H-10 |
1.9 |
7,2 |
15
000 |
1040 |
20
000 |
1380 |
1800 |
1800 |
| PF4205H-10 |
3.2 |
12,1 |
15
000 |
1040 |
20
000 |
1380 |
1800 |
1800 |
| PF4208H-10 |
4.9 |
18,5 |
12
000 |
830 |
17
000 |
1170 |
1800 |
1800 |
| PF4209H-10 |
5.6 |
21,2 |
12
000 |
830 |
17
000 |
1170 |
1800 |
1800 |
| PF4210H-10 |
6.5 |
24,6 |
10
000 |
700 |
15
000 |
1040 |
1800 |
1800 |
|
|
PF4300
Series Pumps for Water-Based Fluids (more
information) |
|
S.A.E.
Outlet Port: |
| PF4303-11 |
2.2 |
8,3 |
8000 |
560 |
8000 |
560 |
1200 |
1800 |
| PF4304-11 |
3.2 |
12,1 |
8000 |
560 |
8000 |
560 |
1200 |
1800 |
| PF4305-11 |
3.7 |
14,0 |
8000 |
560 |
8000 |
560 |
1200 |
1800 |
| PF4306-11 |
4.6 |
17,4 |
8000 |
560 |
8000 |
560 |
1200 |
1800 |
| PF4308-11 |
5.4 |
20,4 |
8000 |
560 |
8000 |
560 |
1200 |
1800 |
| PF4309-11 |
6.0 |
22,7 |
8000 |
560 |
8000 |
560 |
1200 |
1800 |
| PF4310-11 |
6.8 |
25,7 |
8000 |
560 |
8000 |
560 |
1200 |
1800 |
| PF4312-11 |
8.2 |
31,0 |
8000 |
560 |
8000 |
560 |
1200 |
1800 |
|
|
Autoclave/Butech or British Standard Pipe Outlet Port: |
| PF4303H-11 |
2.0 |
7,5 |
15 000 |
1040 |
15 000 |
1040 |
1200 |
1800 |
| PF4304H-11 |
3.1 |
11,7 |
12 000 |
830 |
12 000 |
830 |
1200 |
1800 |
| PF4305H-11 |
3.6 |
13,6 |
10 000 |
700 |
10 000 |
700 |
1200 |
1800 |
| PF4306H-11 |
4.4 |
16,6 |
10 000 |
700 |
10 000 |
700 |
1200 |
1800 |
| PF4308H-11 |
5.3 |
19,9 |
10 000 |
700 |
10 000 |
700 |
1200 |
1800 |
| PF4309H-11 |
5.9 |
22,3 |
10 000 |
700 |
10 000 |
700 |
1200 |
1800 |
| PF4310H-11 |
6.7 |
25,3 |
10 000 |
700 |
10 000 |
700 |
1200 |
1800 |
| PF4312H-11 |
8.1 |
30,7 |
10 000 |
700 |
10 000 |
700 |
1200 |
1800 |
|
| PF6000
Series |
|
Outlet
Block Kit with Autoclave/Butech Port Required: |
| PF6023-3167 |
12.7 |
48,0 |
15 000 |
1040 |
15 000 |
1040 |
1800 |
1800 |
|
|
Outlet
Block Kit with S.A.E., Autoclave/Butech or British Standard
Pipe Port Required: |
| PF6033-3169 |
22.0 |
83,2 |
10 000 |
700 |
10 000 |
700 |
1800 |
1800 |
| PF6046-3174 |
31.3 |
118,4 |
8000 |
560 |
8000 |
560 |
1800 |
1800 |
|
|
Standard
S.A.E. 4-Bolt Flange Inlet and Outlet Ports: |
| PF6054-2946 |
35.4 |
134,0 |
6000 |
420 |
6000 |
420 |
1800 |
2400 |
| PF6070-3186 |
47.6 |
180,1 |
6000 |
420 |
6000 |
420 |
1800 |
2300 |
| PF6080-2989 |
54.0 |
204,4 |
5500 |
380 |
5500 |
380 |
1800 |
2200 |
|
Pump
Selection Notes
- Output
flows are based on typical performance at rated pressure with
pressurized inlet where required.
- Pumps
listed are the most common models with keyed shafts.
- Ordering
pumps with "10" or "30" design/modification
numbers requires a
complete
model code specifying drive shaft, seal and port options.
- Models
with the high pressure "H" option require the use
of outlet port option "A" (Autoclave/Butech fitting)
or "B" (British Standard Pipe fitting). Pumps with
ports for standard S.A.E. fittings are not recommended for
operation above 8000 psi (560 bar). Contact the fitting manufacturer
for the pressure rating of the fitting.
Variable
Delivery Pumps
Split-Flow® Multiple Outlet Pumps
|
|
Dynex/Rivett
Inc.
Pewaukee,
WI USA
Ashland, MA USA
Eaton Socon, Cambs. UK
|
|
|
 |
|
Home
| Site Map | Product
Index |
Power Units
| Find a Distributor
| About Dynex | Contact
Dynex | Literature | Careers
Copyright © 2011 -
DYNEX/RIVETT INC.
|
|