Selection Table - Fixed Displacement Pumps

Pump
Models
Flow at
1800 rpm
Rated Pressure
Maximum
Intermittent
Pressure
Rated
Speed
(rpm)
Maxi-
mum
Speed
(rpm)
U.S. gpm
L/min
psi
bar
psi
bar
 
  PF500 Series (more information)
   S.A.E. Outlet Port:
   PF501-11
0.21
0,79
8000
560
8000
560
1800
3600
   PF504-11
0.34
1,28
8000
560
8000
560
1800
3600
   PF507-11
0.46
1,76
8000
560
8000
560
1800
3600
   PF510-11
0.69
2,59
8000
560
8000
560
1800
3600

   Autoclave/Butech or British Standard Pipe Outlet Port:
   PF501H-11
0.20
0,75
10 000
700
15 000
1040
1800
3600
   PF504H-11
0.32
1,22
10 000
700
15 000
1040
1800
3600
   PF507H-11
0.45
1,70
10 000
700
15 000
1040
1800
3600
   PF510H-11
0.67
2,52
10 000
700
15 000
1040
1800
3600

  PF1000 Series (more information)
   S.A.E. Outlet Port:
   PF1002-10
1.5
5,7
6000
420
8000
560
1800
3600
   PF1003-10
2.1
7,9
6000
420
8000
560
1800
3600
   PF1004-10
2.6
9,8
6000
420
8000
560
1800
3600
   PF1005-10
3.5
13,2
6000
420
8000
560
1800
2800
   PF1006-10
4.1
15,5
6000
420
8000
560
1800
2800
   PF1007-10
5.0
18,9
4000
280
6000
420
1800
2800
   PF1008-10
5.9
22,3
4000
280
6000
420
1800
2800

   Autoclave/Butech or British Standard Pipe Outlet Port:
   PF1002H-10
1.5
5,7
6000
420
10 000
700
1800
3600
   PF1003H-10
2.1
7,9
6000
420
10 000
700
1800
3600
   PF1004H-10
2.6
9,8
6000
420
10 000
700
1800
3600
   PF1005H-10
3.5
13,2
6000
420
10 000
700
1800
2800
   PF1006H-10
4.1
15,5
6000
420
10 000
700
1800
2800

  PF1300 Series Pumps for Water-Based Fluids (more information)
   S.A.E. Outlet Port:
   PF1301-10
0.31
1,18
8000
560
8000
560
1800
1800
   PF1303-10
0.43
1,63
8000
560
8000
560
1800
1800
   PF1305-10
0.55
2,08
8000
560
8000
560
1800
1800
   PF1308-10
0.73
2,76
8000
560
8000
560
1800
1800
   PF1315-10
0.91
3,45
8000
560
8000
560
1800
1800
   PF1318-10
1.21
4,58
8000
560
8000
560
1800
1800
   PF1320-10
1.42
5,37
8000
560
8000
560
1800
1800

   Autoclave/Butech or British Standard Pipe Outlet Port:
   PF1301H-10
0.30
1,14
10 000  
700
10 000   
700
1800
1800
   PF1303H-10
0.42
1,58
10 000  
700
10 000   
700
1800
1800
   PF1305H-10
0.54
2,03
10 000  
700
10 000   
700
1800
1800
   PF1308H-10
0.72
2,73
9000  
630
9000   
630
1800
1800
   PF1315H-10
0.89
3,73
10 000  
700
10 000   
700
1800
1800
   PF1318H-10
1.20
4,54
9000  
630
9000   
630
1800
1800

  PF2000 Series
   S.A.E. Outlet Port:
   PF2007-2190
4.1
15,5
6000
420
6000
420
2000
2800
   PF2008-2191
5.8
22,0
5000
350
6000
420
2000
2400
   PF2009-2184
6.1
23,1
3000
210
4000
280
2000
2800
   PF2012-2185
8.5
32,2
3000
210
4000
280
2000
2400

   Autoclave/Butech Outlet Port:
   PF2007-2973
4.1
15,5
6000
420
10 000
700
1800
2800

   British Standard Pipe Outlet Port:
   PF2007-3055
4.1
15,5
6000
420
10 000
700
1800
2800

   Special Mounting Models:
   S.A.E. Outlet Port:
   PF2006-1808
4.0
15,1
6000
420
8000
560
2000
2400
   PF2008-1804
5.7
21,6
3000
210
5000
350
2000
2400

  PF3000 Series (more information)
   S.A.E. Outlet Port:
   PF3011-10
8.1
30,7
6000
420
8000
560
1800
2800
   PF3015-10
10.0
37,8
6000
420
8000
560
1800
2500
   PF3017-10
12.0
45,4
6000
420
8000
560
1800
2200
   PF3021-10
14.4
54,5
4000
280
6000
420
1800
2500
   PF3024-10
17.2
65,1
4000
280
6000
420
1800
2200

   Autoclave/Butech or British Standard Pipe Outlet Port:
   PF3011H-10
8.1
30,7
6000
420
10 000
700
1800
2800
   PF3015H-10
10.0
37,8
6000
420
10 000
700
1800
2500

  PF4000 Series (more information)
   S.A.E. Outlet Port:
   PF4011-30
7.7
29,1
6000
420
8000
560
1800
2400
   PF4016-30
11.1
42,0
6000
420
8000
560
1800
2400
   PF4018-30
12.4
46,9
6000
420
8000
560
1800
2400
   PF4020-30
14.0
53,0
6000
420
8000
560
1800
2400

   Autoclave/Butech or British Standard PipeOutlet Port:
   PF4011H-30
7.3
27,6
10 000  
700
10 000
700
1800
2400
   PF4016H-30
10.5
39,7
10 000  
700
10 000
700
1800
2400
   PF4018H-30
12.1
45,8
8000  
560
10 000
700
1800
2400
   PF4020H-30
13.7
51,9
8000  
560
10 000
700
1800
2400

  PF4200 Series
   S.A.E. Outlet Port:
   PF4203-10
2.2
8,3
8000
560
8000
560
1800
1800
   PF4205-10
3.6
13,6
8000
560
8000
560
1800
1800
   PF4208-10
5.2
19,7
8000
560
8000
560
1800
1800
   PF4209-10
5.9
22,3
8000
560
8000
560
1800
1800
   PF4210-10
6.7
25,4
8000
560
8000
560
1800
1800

   Autoclave/Butech or British Standard Pipe Outlet Port:
   PF4203H-10
1.9
7,2
15 000
1040  
20 000
1380
1800
1800
   PF4205H-10
3.2
12,1
15 000
1040  
20 000
1380
1800
1800
   PF4208H-10
4.9
18,5
12 000
830  
17 000
1170
1800
1800
   PF4209H-10
5.6
21,2
12 000
830  
17 000
1170
1800
1800
   PF4210H-10
6.5
24,6
10 000
700  
15 000
1040
1800
1800

  PF4300 Series Pumps for Water-Based Fluids (more information)
   S.A.E. Outlet Port:
   PF4303-11
2.2
8,3
8000
560
8000
560
1200
1800
   PF4304-11
3.2
12,1
8000
560
8000
560
1200
1800
   PF4305-11
3.7
14,0
8000
560
8000
560
1200
1800
   PF4306-11
4.6
17,4
8000
560
8000
560
1200
1800
   PF4308-11
5.4
20,4
8000
560
8000
560
1200
1800
   PF4309-11
6.0
22,7
8000
560
8000
560
1200
1800
   PF4310-11
6.8
25,7
8000
560
8000
560
1200
1800
   PF4312-11
8.2
31,0
8000
560
8000
560
1200
1800

   Autoclave/Butech or British Standard Pipe Outlet Port:
   PF4303H-11
2.0
7,5
15 000
1040  
15 000
1040  
1200
1800
   PF4304H-11
3.1
11,7
12 000
830
12 000
830
1200
1800
   PF4305H-11
3.6
13,6
10 000
700
10 000
700
1200
1800
   PF4306H-11
4.4
16,6
10 000
700
10 000
700
1200
1800
   PF4308H-11
5.3
19,9
10 000
700
10 000
700
1200
1800
   PF4309H-11
5.9
22,3
10 000
700
10 000
700
1200
1800
   PF4310H-11
6.7
25,3
10 000
700
10 000
700
1200
1800
   PF4312H-11
8.1
30,7
10 000
700
10 000
700
1200
1800

  PF6000 Series
   Outlet Block Kit with Autoclave/Butech Port Required:
   PF6023-3167
12.7
48,0
15 000
1040
15 000
1040
1800
1800

   Outlet Block Kit with S.A.E., Autoclave/Butech or British Standard Pipe Port Required:
   PF6033-3169
22.0
83,2
10 000  
700
10 000  
700
1800
1800
   PF6046-3174
31.3
118,4
8000  
560
8000  
560
1800
1800

   Standard S.A.E. 4-Bolt Flange Inlet and Outlet Ports:
   PF6054-2946
35.4
134,0
6000
420
6000
420
1800
2400
   PF6070-3186
47.6
180,1
6000
420
6000
420
1800
2300
   PF6080-2989
54.0
204,4
5500
380
5500
380
1800
2200

Pump Selection Notes

  • Output flows are based on typical performance at rated pressure with pressurized inlet where required.
  • Pumps listed are the most common models with keyed shafts.
  • Ordering pumps with "10" or "30" design/modification numbers requires a complete model code specifying drive shaft, seal and port options.
  • Models with the high pressure "H" option require the use of outlet port option "A" (Autoclave/Butech fitting) or "B" (British Standard Pipe fitting). Pumps with ports for standard S.A.E. fittings are not recommended for operation above 8000 psi (560 bar). Contact the fitting manufacturer for the pressure rating of the fitting.

Variable Delivery Pumps     Split-Flow® Multiple Outlet Pumps


Dynex/Rivett Inc.
Pewaukee, WI  USA
Ashland, MA USA
Eaton Socon, Cambs. UK

 
 
Home | Site Map | Product Index | Power Units | Find a Distributor | About Dynex | Contact Dynex | Literature | Careers

Copyright © 2011 - DYNEX/RIVETT INC.